Hydrant systems with D19 and D25 semi-rigid hose

Hydrant systems with D19 and D25 semi-rigid hose

Product enquiries

If you have questions about this product feel free to contact us:

Phone: +420 466 985 890

E-mail: office@phhp.cz


Approved to ČSN 73 0873 and ČSN EN 671-1

Fire hydrant system with semi-rigid hose is a very effective fire-fighting facility with an uninterrupted supply of water  immediately. The design of the system allows quick operation by a single person.

  1. Hydrant cabinet – made of 1 mm steel sheet. Pressurized water supply, brought through the centre of the reel, enabling immediate use of the system. Powder coated surface treatment designed for indoor environment (outdoor design possible by agreement with the manufacturer)
    Solid or glass-panelled door
  2. 19 or 25 mm PH – stabil D semi-rigid hose
  3. Nickel-plated brass ball valve
  4. D 25 spray fire nozzle consisting of a polypropylene body and revolving head. The revolving head enables the user to set a full or spray stream with an adjustable spraying angle within the range 0 – 110° and to shut off the nozzle.
  5. Connection hose used to connect the system to water main

Dimensions:

width x height x depth

Hydrant system with D19 mm semi-rigid hose

  • 650 x 650 x 175 mm – 20 or 30-m hose can be used
  • 710 x 710 x 135 mm – only 20-m hose can be used
    Only fire nozzle with 6 mm equiv. diam. is used – flow rate Q < 1.1 L/sec

Hydrant system with D25 mm semi-rigid hose

  • 650 x 650 x 210 mm – only 20-m hose can be used
  • 650 x 650 x 285 mm – 20 or 30-m hose can be used
  • 710 x 710 x 245 mm – 20 or 30-m hose can be used
    Nozzle options: equiv. 6 mm diam. – flow rate Q < 1.1 L/sec
    equiv. 10 mm diam. – flow rate Q > 1.1 L/sec

Inspection of hydrant system is to be undertaken by a trained person in accordance with applicable standards and regulations.

Hydrant systems with D19 and D25 semi-rigid hose

Dimensions Door Hose Fire nozzle Cat. No.
650x650x175 solid 20m of D19 equiv. 6 svv 101
650x650x175 solid 30m of D19 equiv. 6 svv 102
710x710x135 solid 20m of D19 equiv. 6 svv 110
650x650x210 solid 20m of D25 equiv. 6 svv 005
650x650x210 solid 20m of D25 equiv. 10 svv 006
710x710x245 solid 30m of D25 equiv. 6 svv 016
710x710x245 solid 30m of D25 equiv. 10 svv 010
650x650x175 glass-panelled 20m of D19 equiv. 6 svv 103
650x650x175 glass-panelled 30m of D19 equiv. 6 svv 104
710x710x135 glass-panelled 20m of D19 equiv. 6 svv 111
650x650x210 glass-panelled 20m of D25 equiv. 6 svv 051
650x650x210 glass-panelled 20m of D25 equiv. 10 svv 007
710x710x245 glass-panelled 30m of D25 equiv. 6 svv 008
710x710x245 glass-panelled 30m of D25 equiv. 10 svv 052


650x650x285 hydrant systems with D25 semi-rigid hose

Material Door Hose Fire nozzle Cat. No.
Powder-coated steel solid 20m of D25 equiv. 6 svv 001
Powder-coated steel solid 20m of D25 equiv. 10 svv 002
Powder-coated steel solid 30m of D25 equiv. 6 svv 003
Powder-coated steel solid 30m of D25 equiv. 10 svv 004
Powder-coated steel glass-panelled 20m of D25 equiv. 6 svv 027
Powder-coated steel glass-panelled 20m of D25 equiv. 10 svv 011
Powder-coated steel glass-panelled 30m of D25 equiv. 6 svv 029
Powder-coated steel glass-panelled 30m of D25 equiv. 10 svv 012

Note: Cabinet colour – RAL 3000 (red) – textured, RAL 9003 (white) – textured

Hydrant systems with DN19 and DN25 semi-rigid hose Hydrant systems with DN19 and DN25 semi-rigid hose

System installation:

When selecting a specific type of equipment, systems with at least 25 mm hose (internal diameter) are to be installed especially in the following areas:

a) Fire sections in production facilities (according to ČSN 73 0804) and warehouses (according to ČSN 73 0845)

b) Fire sections (buildings) where the linear speed of fire propagation is v1 > 1.2 m/min; values of v1 from Table B.1 in Appendix B can be used without additional certificates

c) In buildings or their parts designed as:

  1. Indoor meeting areas (according to ČSN 73 0831)
  2. Accommodation buildings of OB 4 group (according to ČSN 73 0833)
  3. Retail outlets and distribution depots
  4. Multiple garages
  5. Exhibition grounds
  6. Film, TV and radio studios
  7. Stages, backstage areas, scene-docks
  8. Fire sections on underground floors with more than 10 persons present (ČSN 73 0818)
  9. Fire sections with high fire load (p > 120 kg/m2)

In other relevant cases, it is sufficient to install hose systems using 19 mm (nominal internal diameter) hose at least.

The hose reel systems are to be installed at a height betw. 1.1 m and 1.3 m above the floor (measured to the centre of equipment). Their position should allow easy reach and it should be possible to open the door up to 180°. For the installation it is necessary to provide sufficient water supply so that a minimum overpressure of 0.2 MPa is guaranteed in the least favourable place.

Application:

After opening the cabinet and checking that the nozzle is shut off, open the ball valve on the inlet (the system fills with water). Unwind the required length of hose from the reel up to the place of fire and turn the head of the nozzle to adjust the required shape of water stream.

Product enquiries

Your first name and surname: *
Your e-mail address: *
Your enquiry/message: *
 
 
Control code: *

Fields marked as (*) are mandatory.

After clicking on "Send" the message will be sent to our e-mail. You can expect our response within 2 working days. But mostly it will take only a few hours.


Are you not sure?

Tel.: +420 466 985 890
+420 466 985 981
+420 466 985 892
Fax: +420 466 985 367
GSM: +420 602 661 103
E-mail: office@phhp.cz

Opening hours:

Monday - Friday       7.00AM - 3.30PM


Site map Optimalizace pro vyhledávače eBRÁNA s.r.o. Tvorba www stránek eBRÁNA s.r.o.

Bezpečnostní agentury | Čerpadla za pozoruhodnou cenu | Kanalizační šachty | Ocelové konstrukce | Požární bezpečnost | Pračky | Regály a regálové systémy | Solární ohřev vody