Fire hydrant system with semi-rigid hose is a very effective fire-fighting facility with an uninterrupted supply of water immediately.

Approved to ČSN 73 0873 and ČSN EN 671-1

Fire hydrant system with semi-rigid hose is a very effective fire-fighting facility with an uninterrupted supply of water  immediately. The design of the system allows quick operation by a single person.

  1. Hydrant cabinet – made of 1 mm steel sheet. Pressurized water supply, brought through the centre of the reel, enabling immediate use of the system. Powder coated surface treatment designed for indoor environment (outdoor design possible by agreement with the manufacturer). Solid or glass-panelled door.
  2. 19 or 25 mm PH – stabil D semi-rigid hose.
  3. Nickel-plated brass ball valve.
  4. D 25 spray fire nozzle consisting of a polypropylene body and revolving head. The revolving head enables the user to set a full or spray stream with an adjustable spraying angle within the range 0 – 110° and to shut off the nozzle.
  5. Connection hose used to connect the system to water main.

Dimensions

width x height x depth

Hydrant system with D19 mm semi-rigid hose

  • 650 x 650 x 175 mm – 20 or 30 m hose can be used.
  • 710 x 710 x 135 mm – only 20 m hose can be used. Only fire nozzle with 6 mm equiv. diam. is used – flow rate Q < 1.1 L/sec.

Hydrant system with D25 mm semi-rigid hose

  • 650 x 650 x 210 mm – only 20 m hose can be used.
  • 650 x 650 x 285 mm – 20 or 30 m hose can be used.
  • 710 x 710 x 245 mm – 20 or 30 m hose can be used. Nozzle options: equiv. 6 mm diam. – flow rate Q < 1.1 L/sec equiv. 10 mm diam. – flow rate Q > 1.1 L/sec.

Inspection of hydrant system is to be undertaken by a trained person in accordance with applicable standards and regulations.

Hydrant systems with D19 and D25 semi-rigid hose

DimensionsDoorHoseFire nozzleCat No.
650 x 650 x 175solid20m of D19equiv. 6svv 101
650 x 650 x 175solid30m of D19equiv. 6svv 102
710 x 710 x 135solid20m of D19equiv. 6svv 110
650 x 650 x 210solid20m of D25equiv. 6svv 005
650 x 650 x 210solid20m of D25equiv. 10svv 006
710 x 710 x 245solid30m of D25equiv. 6svv 016
710 x 710 x 245solid30m of D25equiv. 10svv 010
650 x 650 x 175glass-panelled20m of D19equiv. 6svv 103
650 x 650 x 175glass-panelled30m of D19equiv. 6svv 104
710 x 710 x 135glass-panelled20m of D19equiv. 6svv 111
650 x 650 x 210glass-panelled20m of D25equiv. 6svv 051
650 x 650 x 210glass-panelled20m of D25equiv. 10svv 007
710 x 710 x 245glass-panelled30m of D25equiv. 6svv 008
710 x 710 x 245glass-panelled30m of D25equiv. 10svv 052

650x650x285 hydrant systems with D25 semi-rigid hose

MaterialDoorHoseFire nozzleCat No.
Powder-coated steelsolid20m of D25equiv. 6svv 001
Powder-coated steelsolid20m of D25equiv. 10svv 002
Powder-coated steelsolid30m of D25equiv. 6svv 003
Powder-coated steelsolid30m of D25equiv. 10svv 004
Powder-coated steelglass-panelled20m of D25equiv. 6svv 027
Powder-coated steelglass-panelled20m of D25equiv. 10svv 011
Powder-coated steelglass-panelled30m of D25equiv. 6svv 029
Powder-coated steelglass-panelled30m of D25equiv. 10svv 012
Cabinet colour – RAL 3000 (red) – textured
Cabinet colour – RAL 3000 (red) – textured
Cabinet colour – 9003 (white) – textured
Cabinet colour – 9003 (white) – textured

System installation

When selecting a specific type of equipment, systems with at least 25 mm hose (internal diameter) are to be installed especially in the following areas:

  • Fire sections in production facilities (according to ČSN 73 0804) and warehouses (according to ČSN 73 0845).
  • Fire sections (buildings) where the linear speed of fire propagation is v1 > 1.2 m/min; values of v1 from Table B.1 in Appendix B can be used without additional certificates.

In buildings or their parts designed as:

  1. Indoor meeting areas (according to ČSN 73 0831).
  2. Accommodation buildings of OB 4 group (according to ČSN 73 0833).
  3. Retail outlets and distribution depots.
  4. Multiple garages.
  5. Exhibition grounds.
  6. Film, TV and radio studios.
  7. Stages, backstage areas, scene-docks.
  8. Fire sections on underground floors with more than 10 persons present (ČSN 73 0818).
  9. Fire sections with high fire load (p > 120 kg/m2).

In other relevant cases, it is sufficient to install hose systems using 19 mm (nominal internal diameter) hose at least.

The hose reel systems are to be installed at a height betw. 1.1 m and 1.3 m above the floor (measured to the centre of equipment). Their position should allow easy reach and it should be possible to open the door up to 180°. For the installation it is necessary to provide sufficient water supply so that a minimum overpressure of 0.2 MPa is guaranteed in the least favourable place.

Application

After opening the cabinet and checking that the nozzle is shut off, open the ball valve on the inlet (the system fills with water). Unwind the required length of hose from the reel up to the place of fire and turn the head of the nozzle to adjust the required shape of water stream.

Downloads

HS 710x7100x245pdf214.21 KB
HS 710x7100x135pdf278.64 KB
HS 650x650x285pdf183.72 KB
HS 650x650x210pdf244.70 KB
HS 650x650x175pdf203.96 KB